About this product
Can be used with up to 15 lpm
Delivers up to a 4:1 savings ratio
Comfortable alternative to a mask
Reduces cost of providing oxygen therapy
Lower flow rates reducing common side effects
Compatible with cylinders, concentrators and liquid oxygen
Proven efficacy for use at rest, during sleep and exercise
No batteries required
Max. Inlet Pressure - 345 kPa (3.45 bar, 50 psi)
Max. Flow (LPM) - 15 LPM
Operational Temp. - 5-40C (41-104F)
Operational Humidity - 15-93% non-condensing
Storage Temp. -14C to 70C (-13F to 158F)
Storage Humidity <= 93% non-condensing
The Oxymizer® pendant cannula is a disposable oxygen conserving device used in the routine nasal administration of supplemental oxygen.
The Oxymizer® enables the delivery of continuous high-flow oxygen via a non-mechanical pulse dosing method that can be used in the home, hospital or long-term care settings.
It contains an oxygen conserving reservoir in a fully sealed pendant, which when being used sits comfortably on the chest.
Once the Oxymizer is connected to a continuous flow (CF) oxygen source, the conserving reservoir fills with up to 30ml of oxygen during the patient's exhalation phase. The oxygen is then released from the conserving reservoir by means of a membrane as soon as the patient starts to inhale.
Using the Oxymizer Conserver with a bolus of up to 30ml, allows the adjustment of oxygen delivery that will improve both therapy efficiency and operational costs when used with all LTOT (Long Term Oxygen Therapy) methods.
SKU - P-224
Oxymizer
- Regular price
- £0.00
- Sale price
- £0.00
- Regular price
-
£0.00
The Oxymizer® pendant cannula is a disposable oxygen conserving device used in the routine nasal administration of supplemental oxygen.
The Oxymizer® enables the delivery of continuous high-flow oxygen via a non-mechanical pulse dosing method that can be used in the home, hospital or long-term care settings.
It contains an oxygen conserving reservoir in a fully sealed pendant, which when being used sits comfortably on the chest.
Once the Oxymizer is connected to a continuous flow (CF) oxygen source, the conserving reservoir fills with up to 30ml of oxygen during the patient's exhalation phase. The oxygen is then released from the conserving reservoir by means of a membrane as soon as the patient starts to inhale.
Using the Oxymizer Conserver with a bolus of up to 30ml, allows the adjustment of oxygen delivery that will improve both therapy efficiency and operational costs when used with all LTOT (Long Term Oxygen Therapy) methods.